Skip to main content
BuildAI reviewed Jul 21, 2026

REG-SAMD-CLIN

Guide **Software as a Medical Device (SaMD)** and **software in devices** for **clinical evaluation** expectations: intended use, SaMD category (IMDRF framework), evidence of **analytical and clinical validity** where applicable, and alignment with **EU MDR Annex XIV** clinical evaluation and **FDA** premarket clinical/benefit-risk expectations for software-driven diagnostics and monitoring.

v1.0.0New

Unsigned, install at your own risk

Unverified

This skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.

Install this skill

No account required. Pick your tool, or use the command that detects it for you.

Run in your terminal. It detects your AI tool.

npx @skills-hub-ai/cli install meddev-skills-reg-samd-clin
Or get the file:
Browse all CLI commands →
Manual setup by platform

Claude Code

~/.claude/skills/meddev-skills-reg-samd-clin/SKILL.md

Setup guide →
0Save

Instructions

SaMD, Intended Use, and Clinical Evaluation

Purpose

Guide Software as a Medical Device (SaMD) and software in devices for clinical evaluation expectations: intended use, SaMD category (IMDRF framework), evidence of analytical and clinical validity where applicable, and alignment with EU MDR Annex XIV clinical evaluation and FDA premarket clinical/benefit-risk expectations for software-driven diagnostics and monitoring.

When to Apply

  • Standalone SaMD (no hardware) or software that drives clinical decisions.
  • Changes to intended medical purpose, indications, or output claims.
  • Preparing CER (EU) or clinical sections of 510(k)/De Novo/PMA (US).
  • Mapping SaMD normalization of risk (IMDRF) to ISO 14971.

Requirements (testable)

  1. Intended Use: Document who, what, when, where, why for the software function; freeze claims that drive classification and evidence. Rationale: drives regulatory pathway and clinical scope.
  2. SaMD Category (IMDRF): Assign category per SaMD: Possible Framework for Risk Categorization and Considerations (N41) using state of healthcare situation/condition and significance of information provided; document rationale. Rationale: proportionate evidence.
  3. Analytical Validation: For software processing inputs (signals, images, labs), define analytical performance (accuracy, precision, robustness) vs. predetermined acceptance criteria. Rationale: valid input-to-output mapping.
  4. Clinical Validation: Define clinical association and, where applicable, clinical validation per state-of-the-art (e.g., concordance with reference, outcomes); tie to risk controls and labeling. Rationale: supports safety and performance claims.
  5. EU Clinical Evaluation: Maintain clinical evaluation per MDR Annex XIV and relevant MDCG guidance; update with PMS data; link software changes to CER revision triggers. Rationale: MDR conformity.
  6. US Premarket Clinical Evidence: Align with FDA expectations for the device type (e.g., 510(k) clinical data when needed, De Novo clinical/benefit-risk, PMA clinical trials); cross-reference software V&V with clinical study protocols when software is the intervention. Rationale: submission completeness.
  7. PMCF / Post-Market: Define PMCF needs for SaMD when residual risks or uncertainties exist (EU); plan real-world performance monitoring where claims require ongoing evidence. Rationale: lifecycle closure.

Recommended Practices

  • Maintain a claim matrix: each marketing claim → evidence source (bench, clinical study, literature).
  • Version modeling assumptions (population, prevalence) with software releases when outputs are prevalence-sensitive.

Patterns

Claim-to-evidence row (CSV excerpt):

CLAIM-ID,STATEMENT,EVIDENCE-REF,STATUS
CL-01,"Detects atrial fibrillation in adults 18+",VAL-AFIB-2025-03,approved
CL-02,"Suitable for emergency triage without clinician",,blocked_pending_CER

Intended use snippet (markdown):

## Intended use
- Population: adults 22–80 with diagnosed hypertension under clinician care
- Function: trend BP and flag sustained elevations per rule-set RS-1.2
- Environment: home and outpatient; not for acute emergency diagnosis
- Output: notifications to patient and summary to clinician portal

Anti-Patterns (risks)

  • Indication creep in marketing without CER/DHF update — risk: misbranding / NB major NC.
  • Conflating verification (software tests) with clinical validation — risk: insufficient clinical evidence for claims.
  • Ignoring regulatory class change when SaMD function changes (e.g., Rule 11) — risk: wrong conformity route.

Verification Checklist

  • Intended use and indications match approved/declared scope.
  • IMDRF SaMD category (or equivalent rationale) documented.
  • Analytical/clinical validation plans and reports current for claimed performance.
  • EU CER / US clinical sections cross-reference software version and risk file.
  • PMCF/PMS triggers defined for residual clinical uncertainties.

Traceability

  • IDs: CL-CLAIM-###, CER-###, VAL-CLIN-###; link to REQ-*, RISK-*, release tags.

References

  • IMDRF/SaMD WG documents (e.g., SaMD categorization framework; key definitions).
  • EU MDR 2017/745 Annex XIV (clinical evaluation); MDCG clinical evaluation guidance (verify current revision).
  • FDA Guidance: “Content of Premarket Submissions for Device Software Functions” (2023).
  • FDA Guidance: “Clinical Decision Support Software” (2022) — scope and enforcement policy (verify applicability).

Changelog

  • 1.0.0 (2026-03-20): Initial skill for SaMD intended use, IMDRF category, clinical evaluation linkage.
This skill doesn’t include stateful context yet, instructions only. Learn about stateful skills.

Security

Loading security scan...

Reviews (0)

Browse all →
meddev-authenticationDefine secure user/device authentication, session management, and RBAC suitable for medical device risk profiles. Use when working on authentication in medical device software.0 installsmeddev-state-machinesDefine explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. Use when working on state machines in medical device software.0 installsmeddev-change-controlDefine controlled change-request workflow for software: impact analysis, approvals, verification scope, and regulatory submission flags. Configuration identification and baselines are in DOC-SCM (IEC 62304 Clause 8.1, 8.3); approved implementation and re-verification align with 8.2. Use when working on change control in medical device software.0 installsCONN-USBImplement safe USB device connectivity: class selection, enumeration handling, data validation, electrical and safety considerations.0 installsmeddev-ai-ml-medical-device-softwareAddress machine learning inside the regulated product (not LLM coding assistants): Good Machine Learning Practice (GMLP), training/validation data integrity, Predetermined Change Control Plans (PCCP) where applicable, drift monitoring, and linking models to ISO 14971 and software lifecycle controls. Use when working on ai ml medical device software in medical device software.0 installsTEST-HILValidate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.0 installs

More from Medical Device Skills

View source →

More Build skills

Browse category →
senior-frontendBuild and review React, Next.js, TypeScript or Tailwind frontends: components, scaffolding, performance and bundle size. Use whenever the user wants a new component or app, a page feels slow, the bundle is too big, or asks for a frontend code review.642 installsui-design-systemUse when building a design system: tokens, component docs, responsive scales or developer handoff. Generates tokens with design_token_generator.py.546 installsfrontend-designGuidance for distinctive, intentional visual design when building new UI or reshaping an existing one. Helps with aesthetic direction, typography, and making choices that don't read as templated defaults.353 installssenior-backendBuild and fix backend services: REST or GraphQL APIs, auth, microservices, PostgreSQL queries, migrations and load tests. Use whenever the user's API is slow or broken, needs login or auth added, a schema change, or a new endpoint or service scaffolded.252 installsself-improving-agentCurate what the agent has learned into durable project knowledge. Reviews Claude Code auto-memory (MEMORY.md and its topic files) for learnings worth keeping, promotes proven ones into CLAUDE.md or .claude/rules/, records a correction as a lesson that persists across sessions, prunes stale or duplicate entries, and turns a recurring fix into a reusable skill. Use whenever the user asks what you have learned or saved about the project, which memories should become permanent rules, to remember a lesson or stop repeating a mistake, or to clean up, audit or check memory health.180 installsusing-superpowersUse when starting any conversation - establishes how to find and use skills, requiring skill invocation before ANY response including clarifying questions146 installs

Frequently asked questions about REG-SAMD-CLIN

What does the REG-SAMD-CLIN skill do?

Guide **Software as a Medical Device (SaMD)** and **software in devices** for **clinical evaluation** expectations: intended use, SaMD category (IMDRF framework), evidence of **analytical and clinical validity** where applicable, and alignment with **EU MDR Annex XIV** clinical evaluation and **FDA** premarket clinical/benefit-risk expectations for software-driven diagnostics and monitoring. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.

How do I install the REG-SAMD-CLIN skill?

Run `npx @skills-hub-ai/cli install meddev-skills-reg-samd-clin` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-reg-samd-clin/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.

Which AI tools does REG-SAMD-CLIN work with?

REG-SAMD-CLIN runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.

Is the REG-SAMD-CLIN skill free?

Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.

How do I use REG-SAMD-CLIN after installing it?

In Claude Code, type `/meddev-skills-reg-samd-clin` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.

Can I share the REG-SAMD-CLIN skill with my team?

Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.