Validate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.

v1.0.0New

Unsigned, install at your own risk

Unverified

This skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.

Install this skill

No account required. Pick your tool, or use the command that detects it for you.

Run in your terminal. It detects your AI tool.

npx @skills-hub-ai/cli install meddev-skills-test-hil
Or get the file:
Browse all CLI commands →
Manual setup by platform

Claude Code

~/.claude/skills/meddev-skills-test-hil/SKILL.md

Setup guide →
0Save

Instructions

Hardware-in-the-Loop (HIL) Testing

Purpose

Validate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.

When to Apply

  • Before release for safety-relevant features.
  • After hardware/driver changes or timing-sensitive refactors.

Requirements (testable)

  1. Fixture Design: Use representative hardware fixtures with controllable stimuli and measurements; include fault injection paths. Rationale: realism and safety coverage.
  2. Automation: Automate HIL sequences; script stimuli and assertions; capture logs/measurements. Rationale: repeatability and evidence.
  3. Safety Monitoring: Monitor outputs for safety limits; include E-stops; ensure safe state on test failure. Rationale: operator/device safety.
  4. Timing: Measure latencies and deadlines under realistic load; verify against requirements. Rationale: timing assurance.
  5. Parallelization: Where possible, run tests in parallel fixtures; manage resource contention safely. Rationale: efficiency.
  6. Traceability: Link HIL tests to requirements/risks and record configurations (HW rev, firmware rev, calibration). Rationale: reproducibility.

Recommended Practices

  • Use DAQ/logging for analog signals; timestamp with synchronized clocks.
  • Combine HIL with fault injection (disconnects, noise, power dips).
  • Keep fixtures version-controlled (BOM, wiring, firmware).
  • Provide dry-run/simulation mode for CI when hardware not available.

Patterns

HIL test record (YAML):

# REQ-HIL-REC-01
test_id: TEST-HIL-102
reqs: [REQ-62304-102, REQ-FT-WD-01]
hw_rev: "board v2.1"
fw_rev: "1.3.0"
stimuli:
  - type: digital
    signal: door_open
    at_ms: 0
measures:
  - signal: motor_pwm
    expect: 0 within 50ms
result: pass

Fault injection step:

// REQ-HIL-FAULT-02; TEST-HIL-120
At t=500 ms, drop comms line; expect safe state within 200 ms.

Anti-Patterns (risks)

  • Ad-hoc manual HIL with no logs -> risk: non-reproducible results.
  • No safety limits/E-stop during tests -> risk: injury/device damage.
  • Ignoring hardware configuration tracking -> risk: unrepeatable tests.
  • Only ideal conditions tested -> risk: missed real-world faults.

Verification Checklist

  • Fixture representative; stimuli/measurements controlled; fault injection available.
  • Automated scripts/sequences with logged results and timestamps.
  • Safety monitoring and E-stop implemented; safe state on failure.
  • Timing under load measured and within requirements.
  • Parallel execution handled safely; resource conflicts managed.
  • Hardware/firmware/config recorded; tests linked to requirements/risks.

Traceability

  • Map TEST-HIL-### to requirements and hazards; store fixture/config data with results.

References

  • IEC 62304 integration/system testing context.
  • ISO 14971 risk-based verification.

Changelog

  • 1.0.0 (2026-01-04): Initial HIL testing skill with fixture, automation, and safety/timing focus.

Audit History

  • 2026-01-04: Audit performed. Verified:
    • HIL fixture patterns follow industry best practices
    • Safety monitoring and E-stop requirements accurately described
    • Fault injection concepts are appropriate for medical device testing
This skill doesn’t include stateful context yet, instructions only. Learn about stateful skills.

Security

Loading security scan...

Reviews (0)

Browse all →
meddev-authenticationDefine secure user/device authentication, session management, and RBAC suitable for medical device risk profiles. Use when working on authentication in medical device software.0 installsmeddev-state-machinesDefine explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. Use when working on state machines in medical device software.0 installsmeddev-change-controlDefine controlled change-request workflow for software: impact analysis, approvals, verification scope, and regulatory submission flags. Configuration identification and baselines are in DOC-SCM (IEC 62304 Clause 8.1, 8.3); approved implementation and re-verification align with 8.2. Use when working on change control in medical device software.0 installsCONN-USBImplement safe USB device connectivity: class selection, enumeration handling, data validation, electrical and safety considerations.0 installsmeddev-ai-ml-medical-device-softwareAddress machine learning inside the regulated product (not LLM coding assistants): Good Machine Learning Practice (GMLP), training/validation data integrity, Predetermined Change Control Plans (PCCP) where applicable, drift monitoring, and linking models to ISO 14971 and software lifecycle controls. Use when working on ai ml medical device software in medical device software.0 installsTEST-COVERAGEMeasure and enforce coverage appropriate to safety class: statement/branch and MC/DC where applicable, with documented exclusions.0 installs

More from Medical Device Skills

View source →

More Test skills

Browse category →

Frequently asked questions about TEST-HIL

What does the TEST-HIL skill do?

Validate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.

How do I install the TEST-HIL skill?

Run `npx @skills-hub-ai/cli install meddev-skills-test-hil` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-test-hil/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.

Which AI tools does TEST-HIL work with?

TEST-HIL runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.

Is the TEST-HIL skill free?

Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.

How do I use TEST-HIL after installing it?

In Claude Code, type `/meddev-skills-test-hil` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.

Can I share the TEST-HIL skill with my team?

Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.