REG-POSTMKT-LABEL
Connect **post-market** processes to software: **complaints**, **vigilance / MDR reporting**, **recalls and field corrections**, **cybersecurity coordinated disclosure** touchpoints, and **labeling / IFU** (including on-device strings, UDI display, and versioned patient/clinician instructions) so maintenance (IEC 62304 §6) and QMS **CAPA** stay coherent.
Unsigned, install at your own risk
UnverifiedThis skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.
Install this skill
No account required. Pick your tool, or use the command that detects it for you.
Run in your terminal. It detects your AI tool.
npx @skills-hub-ai/cli install meddev-skills-reg-postmkt-labelManual setup by platform
Claude Code
~/.claude/skills/meddev-skills-reg-postmkt-label/SKILL.md
Instructions
Postmarket Surveillance, Complaints, Recalls, and Software Labeling
Purpose
Connect post-market processes to software: complaints, vigilance / MDR reporting, recalls and field corrections, cybersecurity coordinated disclosure touchpoints, and labeling / IFU (including on-device strings, UDI display, and versioned patient/clinician instructions) so maintenance (IEC 62304 §6) and QMS CAPA stay coherent.
When to Apply
- Triaging customer complaints that reference software behavior, crashes, or security.
- Deciding reportability (e.g., EU serious incident criteria; US MDR reports).
- FSCA / recall / UDI correction affecting distributed software.
- Updating Instructions for Use, GUI risk messaging, or release notes with safety information.
- Post-market cybersecurity vulnerability handling tied to deployed versions.
Requirements (testable)
- Complaint Intake: Record software version, hardware rev, environment, and symptom for each complaint; link to risk file and known anomalies; route into software maintenance feedback (IEC 62304 6.2.1). Rationale: investigation and trend analysis.
- Investigation: Perform root cause analysis distinguishing software defect, use error, SOUP/CVE, and environmental factors; preserve records per QMS. Rationale: CAPA effectiveness.
- Vigilance / Reporting: Apply EU MDR vigilance rules and FDA MDR reporting for device malfunctions; escalate per timelines when criteria met. Rationale: legal reporting.
- Field Actions: For FSCA / recall, define affected versions, corrective action (patch, config, instructions), customer communication, and effectiveness checks. Rationale: patient safety.
- Software Corrections & Removals: Track 21 CFR Part 806-style distinctions (US) where applicable; document recall strategy including SaaS/OTA distribution. Rationale: regulatory consistency.
- Labeling Control: Maintain master label and IFU under document control; version with software releases; verify UI strings match approved labeling for risks/warnings. Rationale: misbranding prevention.
- UDI & Version Display: Show UDI / version per MDCG 2018-1 (EU) and firm policy; ensure About screen / splash matches released build. Rationale: traceability to field units.
- Postmarket Cybersecurity: Tie CVE handling, SBOM updates, and patch deployment to PMS and risk review (see FDA cybersecurity postmarket expectations). Rationale: sustained security state.
Recommended Practices
- Single field matrix: version × region × config × known issues.
- Automate extraction of displayed version from build metadata into IFU appendices.
Patterns
Complaint record (YAML):
complaint:
id: "CMP-2026-0142"
sw_version: "2.3.1"
text: "App crashed during upload"
investigation: "ROOT-2026-044"
linked_anomaly: "BUG-778"
reportable: false
capa: "CAPA-2026-09"
IFU change note:
## Document history
| Rev | Software | Change |
|-----|----------|--------|
| H | 2.3.1 | Clarified WiFi reconnection warning (HZ-USE-02) |
Anti-Patterns (risks)
- Closing complaints as user error without usability/risk review — risk: missed use-related hazard.
- Silent on-screen text changes for risk warnings — risk: labeling/QMS violation.
- OTA fix without version traceability or customer list — risk: incomplete FSCA scope.
Verification Checklist
- Complaint records include software version and investigation outcome.
- Reportability assessed per jurisdiction; submissions logged if required.
- Field actions documented with affected versions and communications.
- IFU/label revision matches released software; UI spot-checked.
- UDI/version display verified on device for the release build.
- Cybersecurity patches tied to risk review and customer notification policy.
Traceability
- IDs:
CMP-*,FSCA-*,LBL-*,IFU-*; link tov*.*.*,BUG-*,HZ-*.
References
- IEC 62304:2006+A1:2015, 6.2 (feedback, problem reports, change communication);
DOC-SW-MAINT,DOC-PROBLEM-RES. - EU MDR 2017/745 — vigilance (Articles 87–92), PMS (Articles 83–86).
- FDA 21 CFR Part 803 (medical device reporting) — where applicable.
- FDA 21 CFR Part 806 (reports of corrections/removals).
- MDCG 2018-1 v3 — UDI for software (verify revision).
- FDA “Cybersecurity in Medical Devices” — postmarket expectations (current guidance).
Changelog
- 1.0.1 (2026-05-21): Linked complaint intake to IEC 62304 maintenance process (6.2).
- 1.0.0 (2026-03-20): Initial skill for complaints, vigilance, recalls, labeling/IFU, cybersecurity PMS.
Security
Reviews (0)
Related skills
Browse all →More from Medical Device Skills
View source →More Build skills
Browse category →Frequently asked questions about REG-POSTMKT-LABEL
What does the REG-POSTMKT-LABEL skill do?
Connect **post-market** processes to software: **complaints**, **vigilance / MDR reporting**, **recalls and field corrections**, **cybersecurity coordinated disclosure** touchpoints, and **labeling / IFU** (including on-device strings, UDI display, and versioned patient/clinician instructions) so maintenance (IEC 62304 §6) and QMS **CAPA** stay coherent. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.
How do I install the REG-POSTMKT-LABEL skill?
Run `npx @skills-hub-ai/cli install meddev-skills-reg-postmkt-label` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-reg-postmkt-label/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.
Which AI tools does REG-POSTMKT-LABEL work with?
REG-POSTMKT-LABEL runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.
Is the REG-POSTMKT-LABEL skill free?
Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.
How do I use REG-POSTMKT-LABEL after installing it?
In Claude Code, type `/meddev-skills-reg-postmkt-label` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.
Can I share the REG-POSTMKT-LABEL skill with my team?
Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.