Skip to main content
BuildAI reviewed Jul 21, 2026

REG-POSTMKT-LABEL

Connect **post-market** processes to software: **complaints**, **vigilance / MDR reporting**, **recalls and field corrections**, **cybersecurity coordinated disclosure** touchpoints, and **labeling / IFU** (including on-device strings, UDI display, and versioned patient/clinician instructions) so maintenance (IEC 62304 §6) and QMS **CAPA** stay coherent.

v1.0.1New

Unsigned, install at your own risk

Unverified

This skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.

Install this skill

No account required. Pick your tool, or use the command that detects it for you.

Run in your terminal. It detects your AI tool.

npx @skills-hub-ai/cli install meddev-skills-reg-postmkt-label
Or get the file:
Browse all CLI commands →
Manual setup by platform

Claude Code

~/.claude/skills/meddev-skills-reg-postmkt-label/SKILL.md

Setup guide →
0Save

Instructions

Postmarket Surveillance, Complaints, Recalls, and Software Labeling

Purpose

Connect post-market processes to software: complaints, vigilance / MDR reporting, recalls and field corrections, cybersecurity coordinated disclosure touchpoints, and labeling / IFU (including on-device strings, UDI display, and versioned patient/clinician instructions) so maintenance (IEC 62304 §6) and QMS CAPA stay coherent.

When to Apply

  • Triaging customer complaints that reference software behavior, crashes, or security.
  • Deciding reportability (e.g., EU serious incident criteria; US MDR reports).
  • FSCA / recall / UDI correction affecting distributed software.
  • Updating Instructions for Use, GUI risk messaging, or release notes with safety information.
  • Post-market cybersecurity vulnerability handling tied to deployed versions.

Requirements (testable)

  1. Complaint Intake: Record software version, hardware rev, environment, and symptom for each complaint; link to risk file and known anomalies; route into software maintenance feedback (IEC 62304 6.2.1). Rationale: investigation and trend analysis.
  2. Investigation: Perform root cause analysis distinguishing software defect, use error, SOUP/CVE, and environmental factors; preserve records per QMS. Rationale: CAPA effectiveness.
  3. Vigilance / Reporting: Apply EU MDR vigilance rules and FDA MDR reporting for device malfunctions; escalate per timelines when criteria met. Rationale: legal reporting.
  4. Field Actions: For FSCA / recall, define affected versions, corrective action (patch, config, instructions), customer communication, and effectiveness checks. Rationale: patient safety.
  5. Software Corrections & Removals: Track 21 CFR Part 806-style distinctions (US) where applicable; document recall strategy including SaaS/OTA distribution. Rationale: regulatory consistency.
  6. Labeling Control: Maintain master label and IFU under document control; version with software releases; verify UI strings match approved labeling for risks/warnings. Rationale: misbranding prevention.
  7. UDI & Version Display: Show UDI / version per MDCG 2018-1 (EU) and firm policy; ensure About screen / splash matches released build. Rationale: traceability to field units.
  8. Postmarket Cybersecurity: Tie CVE handling, SBOM updates, and patch deployment to PMS and risk review (see FDA cybersecurity postmarket expectations). Rationale: sustained security state.

Recommended Practices

  • Single field matrix: version × region × config × known issues.
  • Automate extraction of displayed version from build metadata into IFU appendices.

Patterns

Complaint record (YAML):

complaint:
  id: "CMP-2026-0142"
  sw_version: "2.3.1"
  text: "App crashed during upload"
  investigation: "ROOT-2026-044"
  linked_anomaly: "BUG-778"
  reportable: false
  capa: "CAPA-2026-09"

IFU change note:

## Document history
| Rev | Software | Change |
|-----|----------|--------|
| H   | 2.3.1    | Clarified WiFi reconnection warning (HZ-USE-02) |

Anti-Patterns (risks)

  • Closing complaints as user error without usability/risk review — risk: missed use-related hazard.
  • Silent on-screen text changes for risk warnings — risk: labeling/QMS violation.
  • OTA fix without version traceability or customer list — risk: incomplete FSCA scope.

Verification Checklist

  • Complaint records include software version and investigation outcome.
  • Reportability assessed per jurisdiction; submissions logged if required.
  • Field actions documented with affected versions and communications.
  • IFU/label revision matches released software; UI spot-checked.
  • UDI/version display verified on device for the release build.
  • Cybersecurity patches tied to risk review and customer notification policy.

Traceability

  • IDs: CMP-*, FSCA-*, LBL-*, IFU-*; link to v*.*.*, BUG-*, HZ-*.

References

  • IEC 62304:2006+A1:2015, 6.2 (feedback, problem reports, change communication); DOC-SW-MAINT, DOC-PROBLEM-RES.
  • EU MDR 2017/745 — vigilance (Articles 87–92), PMS (Articles 83–86).
  • FDA 21 CFR Part 803 (medical device reporting) — where applicable.
  • FDA 21 CFR Part 806 (reports of corrections/removals).
  • MDCG 2018-1 v3 — UDI for software (verify revision).
  • FDA “Cybersecurity in Medical Devices” — postmarket expectations (current guidance).

Changelog

  • 1.0.1 (2026-05-21): Linked complaint intake to IEC 62304 maintenance process (6.2).
  • 1.0.0 (2026-03-20): Initial skill for complaints, vigilance, recalls, labeling/IFU, cybersecurity PMS.
This skill doesn’t include stateful context yet, instructions only. Learn about stateful skills.

Security

Loading security scan...

Reviews (0)

Browse all →
meddev-authenticationDefine secure user/device authentication, session management, and RBAC suitable for medical device risk profiles. Use when working on authentication in medical device software.0 installsmeddev-state-machinesDefine explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. Use when working on state machines in medical device software.0 installsmeddev-change-controlDefine controlled change-request workflow for software: impact analysis, approvals, verification scope, and regulatory submission flags. Configuration identification and baselines are in DOC-SCM (IEC 62304 Clause 8.1, 8.3); approved implementation and re-verification align with 8.2. Use when working on change control in medical device software.0 installsCONN-USBImplement safe USB device connectivity: class selection, enumeration handling, data validation, electrical and safety considerations.0 installsmeddev-ai-ml-medical-device-softwareAddress machine learning inside the regulated product (not LLM coding assistants): Good Machine Learning Practice (GMLP), training/validation data integrity, Predetermined Change Control Plans (PCCP) where applicable, drift monitoring, and linking models to ISO 14971 and software lifecycle controls. Use when working on ai ml medical device software in medical device software.0 installsTEST-HILValidate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.0 installs

More from Medical Device Skills

View source →

More Build skills

Browse category →
senior-frontendBuild and review React, Next.js, TypeScript or Tailwind frontends: components, scaffolding, performance and bundle size. Use whenever the user wants a new component or app, a page feels slow, the bundle is too big, or asks for a frontend code review.642 installsui-design-systemUse when building a design system: tokens, component docs, responsive scales or developer handoff. Generates tokens with design_token_generator.py.546 installsfrontend-designGuidance for distinctive, intentional visual design when building new UI or reshaping an existing one. Helps with aesthetic direction, typography, and making choices that don't read as templated defaults.353 installssenior-backendBuild and fix backend services: REST or GraphQL APIs, auth, microservices, PostgreSQL queries, migrations and load tests. Use whenever the user's API is slow or broken, needs login or auth added, a schema change, or a new endpoint or service scaffolded.252 installsself-improving-agentCurate what the agent has learned into durable project knowledge. Reviews Claude Code auto-memory (MEMORY.md and its topic files) for learnings worth keeping, promotes proven ones into CLAUDE.md or .claude/rules/, records a correction as a lesson that persists across sessions, prunes stale or duplicate entries, and turns a recurring fix into a reusable skill. Use whenever the user asks what you have learned or saved about the project, which memories should become permanent rules, to remember a lesson or stop repeating a mistake, or to clean up, audit or check memory health.179 installsusing-superpowersUse when starting any conversation - establishes how to find and use skills, requiring skill invocation before ANY response including clarifying questions146 installs

Frequently asked questions about REG-POSTMKT-LABEL

What does the REG-POSTMKT-LABEL skill do?

Connect **post-market** processes to software: **complaints**, **vigilance / MDR reporting**, **recalls and field corrections**, **cybersecurity coordinated disclosure** touchpoints, and **labeling / IFU** (including on-device strings, UDI display, and versioned patient/clinician instructions) so maintenance (IEC 62304 §6) and QMS **CAPA** stay coherent. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.

How do I install the REG-POSTMKT-LABEL skill?

Run `npx @skills-hub-ai/cli install meddev-skills-reg-postmkt-label` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-reg-postmkt-label/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.

Which AI tools does REG-POSTMKT-LABEL work with?

REG-POSTMKT-LABEL runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.

Is the REG-POSTMKT-LABEL skill free?

Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.

How do I use REG-POSTMKT-LABEL after installing it?

In Claude Code, type `/meddev-skills-reg-postmkt-label` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.

Can I share the REG-POSTMKT-LABEL skill with my team?

Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.