REG-21CFR11
Provide implementation guidance for electronic records/signatures (ER/ES) compliance: access control, audit trails, data integrity, and validation expectations in medical device software and supporting tools.
Unsigned, install at your own risk
UnverifiedThis skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.
Install this skill
No account required. Pick your tool, or use the command that detects it for you.
Run in your terminal. It detects your AI tool.
npx @skills-hub-ai/cli install meddev-skills-reg-21cfr11Manual setup by platform
Claude Code
~/.claude/skills/meddev-skills-reg-21cfr11/SKILL.md
Instructions
21 CFR Part 11 Electronic Records and Signatures
Purpose
Provide implementation guidance for electronic records/signatures (ER/ES) compliance: access control, audit trails, data integrity, and validation expectations in medical device software and supporting tools.
When to Apply
- Systems creating, modifying, storing, or transmitting electronic records subject to FDA records.
- Implementing electronic signatures or approvals in software lifecycle tools (e.g., QMS, ALM, CI/CD approvals).
- Handling PHI/PII or regulated data with retention requirements.
Requirements (testable)
- Access Control: Unique user identities; role-based permissions; no shared accounts. Rationale: accountability.
- Authentication Strength: Enforce strong auth (password policy or MFA for remote) appropriate to risk; session timeout and lockout. Rationale: prevent unauthorized use.
- Electronic Signatures: Link signatures to unique user IDs; include printed name, date/time, and meaning of signature (e.g., review/approval) per §11.50. Rationale: non-repudiation.
- Signature Controls: For open systems, require two distinct factors at signing or equivalent control; log signature attempts; prevent reuse of credentials without re-auth (§11.200). Rationale: signature integrity.
- Audit Trails: Computer-generated, time-stamped, secure, and independent audit trail for create/modify/delete; capture user, timestamp, action, before/after where feasible; no alteration by users (§11.10(e)). Rationale: record integrity.
- Record Integrity: Protect records from alteration; use checksums/hashes, versioning, and controlled storage; backups with integrity checks. Rationale: data reliability.
- Time Synchronization: System clocks synchronized (e.g., NTP) for audit and signature timestamps. Rationale: reliable timing.
- Validation: Validate systems for intended use; document requirements, test protocols/results, and deviations (§11.10(a)). Rationale: fitness for use.
- Training & Policies: Users trained on ER/ES use; policies for credentials and signatures documented. Rationale: procedural control.
Recommended Practices
- Use tamper-evident logging (hash chaining, sealed storage).
- Require step-up authentication for high-risk signatures or remote access.
- Implement per-event reason codes for critical record changes.
- Store signature meaning as a controlled vocabulary (e.g., APPROVE, REVIEW).
- Periodically review accounts/roles; disable dormant accounts automatically.
Patterns
Audit log with hash chaining:
// LOG-11: hash-chained audit entry; TEST-AUD-04 validates integrity
typedef struct {
uint8_t prev_hash[32];
uint8_t entry_hash[32];
audit_event_t ev;
} audit_record_t;
Signature capture (conceptual):
// SIG-11: enforce re-auth + meaning capture
int sign_change(const user_t *u, const char *meaning, const char *record_id) {
if (!reauthenticate(u)) return -1; // MFA or password re-prompt
audit_log("SIG_ATTEMPT", u->id, record_id);
if (!is_allowed_meaning(meaning)) return -2; // controlled vocab
return persist_signature(u, meaning, record_id, timestamp_now());
}
Record integrity with checksum:
// REQ-11-INTEGRITY: checksum stored with record
uint32_t checksum_record(const void *buf, size_t len) {
return crc32(buf, len);
}
Anti-Patterns (risks)
- Shared or generic accounts for approvals -> risk: noncompliant signatures.
- Editable audit logs or logs stored with app-level delete rights -> risk: tampering.
- No re-authentication for signatures -> risk: repudiation and misuse.
- Unsynchronized clocks -> risk: unreliable audit trails.
- Unvalidated tools generating submission records -> risk: invalid evidence.
Verification Checklist
- Unique user IDs; RBAC applied; no shared accounts.
- Authentication policy enforced (complexity/MFA as applicable); session timeout/lockout configured.
- Signature records include user, timestamp, meaning; re-authentication enforced.
- Audit trail implemented, immutable/tamper-evident; captures create/modify/delete.
- Record integrity controls (hash/checksum/versioning) in place; backups validated.
- System time synchronized and monitored.
- System validated for intended use with documented test evidence.
- Policies and training documented; access/role reviews performed.
Traceability
- Link ER/ES requirements (
REQ-11-###) to design elements, code, and tests (TEST-11-###). - Keep validation artifacts in configuration control; associate signatures with requirement/test IDs.
- Store audit log integrity verification results with release artifacts.
References
- 21 CFR Part 11 (notably §§11.10, 11.50, 11.200).
- FDA guidance on Part 11 scope and application (2003).
- NIST SP 800-63 (for authentication strength considerations; informative).
Changelog
- 1.0.0 (2026-01-04): Initial skill covering ER/ES access control, signatures, audit, integrity, and validation expectations.
Audit History
- 2026-01-04: Regulatory audit performed. Verified:
- 21 CFR Part 11 section references (§§11.10, 11.50, 11.200) are accurate
- FDA 2003 guidance "Part 11, Electronic Records; Electronic Signatures — Scope and Application" correctly referenced
- Scope of Part 11 relative to predicate rules correctly explained
- NIST SP 800-63 reference appropriate as informative guidance for authentication strength
Security
Reviews (0)
Related skills
Browse all →More from Medical Device Skills
View source →More Build skills
Browse category →Frequently asked questions about REG-21CFR11
What does the REG-21CFR11 skill do?
Provide implementation guidance for electronic records/signatures (ER/ES) compliance: access control, audit trails, data integrity, and validation expectations in medical device software and supporting tools. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.
How do I install the REG-21CFR11 skill?
Run `npx @skills-hub-ai/cli install meddev-skills-reg-21cfr11` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-reg-21cfr11/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.
Which AI tools does REG-21CFR11 work with?
REG-21CFR11 runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.
Is the REG-21CFR11 skill free?
Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.
How do I use REG-21CFR11 after installing it?
In Claude Code, type `/meddev-skills-reg-21cfr11` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.
Can I share the REG-21CFR11 skill with my team?
Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.