Skip to main content
DocsReviewed Jul 21, 2026

DOC-SW-REQ

Guide creation, verification, and maintenance of software system requirements derived from system needs (IEC 62304:2006+A1:2015, 5.2)—with content appropriate to the device, risk controls embedded for Class B/C, and evidence that requirements are testable and traceable.

v1.0.0New

Unsigned, install at your own risk

Unverified

This skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.

Install this skill

No account required. Pick your tool, or use the command that detects it for you.

Run in your terminal. It detects your AI tool.

npx @skills-hub-ai/cli install meddev-skills-doc-sw-req
Or get the file:
Browse all CLI commands →
Manual setup by platform

Claude Code

~/.claude/skills/meddev-skills-doc-sw-req/SKILL.md

Setup guide →
0Save

Instructions

Software Requirements Analysis

Purpose

Guide creation, verification, and maintenance of software system requirements derived from system needs (IEC 62304:2006+A1:2015, 5.2)—with content appropriate to the device, risk controls embedded for Class B/C, and evidence that requirements are testable and traceable.

When to Apply

  • Defining or updating software requirements before design or implementation.
  • Refactoring features that change inputs, outputs, alarms, security, or clinical behaviour.
  • Adding SOUP, connectivity, or UI flows that need explicit software requirements.
  • Preparing verification plans that must cover all software requirements (5.7).

Requirements (testable)

  1. Derive from System Needs [Class A, B, C]: Document software system requirements from system-level needs; for software-only devices, align system and software requirement sets explicitly. Rationale: 5.2.1.
  2. Content Coverage [Class A, B, C]: Address applicable categories—functional capability, inputs/outputs, external interfaces, software-driven alarms/warnings/messages, security, user-interface behaviour, data structures, installation/site constraints, operation/maintenance, IT-network behaviour, user maintenance, and applicable regulatory needs. Rationale: 5.2.2 (interpretation: engineering checklist, not exhaustive copy).
  3. Risk Controls in Requirements [Class B, C]: Include software-implemented risk control measures in requirements when identified by risk management. Rationale: 5.2.3.
  4. Re-evaluate Device Risk [Class A, B, C]: When software requirements are established or materially changed, re-evaluate device risk analysis and update as needed. Rationale: 5.2.4.
  5. Keep System Requirements Current [Class A, B, C]: Re-evaluate and update related system requirements when software requirements change. Rationale: 5.2.5.
  6. Requirements Verification [Class A, B, C]: Verify and document that software requirements implement system needs (including risk controls), are non-contradictory, unambiguous, testable, uniquely identified, and traceable to system requirements or other approved sources. Rationale: 5.2.6.

Recommended Practices

  • Use stable IDs (REQ-62304-###) in a managed file (e.g. requirements.yaml), not only in code comments.
  • Add explicit negative, boundary, and security abuse cases per requirement where safety-relevant.
  • Tag requirements with safety class of the implementing item when known.
  • Cross-reference usability needs (IEC 62366) and cybersecurity expectations in dedicated requirement subsections.

Patterns

Requirement entry (YAML):

requirements:
  - id: REQ-62304-102
    class: Class C
    summary: Stop infusion within 50 ms when door open sensor asserts
    sources: [SYS-REQ-44]
    risk_controls: [RISK-CTRL-19]
    categories: [functional, alarms, timing]
    verification: [TEST-201, TEST-410]
    negative_cases:
      - sensor bounce within 50 ms window
      - door open during self-test

Security and network excerpt:

  - id: REQ-62304-210
    class: Class B
    summary: Reject BLE pairing without LE Secure Connections
    categories: [security, interfaces]
    verification: [TEST-BLE-03]

Anti-Patterns (risks)

  • Requirements only in tickets or chat, not under configuration control -> risk: traceability and audit gaps.
  • Vague acceptance criteria ("fast enough", "secure") -> risk: 5.2.6 verification failure.
  • Missing risk control requirements for Class B/C -> risk: controls implemented but not verified against needs.
  • System requirements not updated when software scope grows -> risk: device-level inconsistency.

Verification Checklist

  • Software requirements derived from documented system needs.
  • Applicable content categories addressed for the device type.
  • Class B/C: software risk controls reflected in requirements.
  • Device risk analysis re-evaluated after requirement changes.
  • System requirements updated when software requirements change.
  • Verification record shows testability, uniqueness, consistency, and traceability.

Traceability

  • Map REQ-### ↔ SYS-REQ-### ↔ HZ-### / RISK-CTRL-### ↔ TEST-### ↔ design (DES-###).
  • See DOC-TRACEABILITY for matrix conventions.

References

  • IEC 62304:2006+A1:2015, 5.2 (software requirements analysis).
  • ISO 14971:2019 (risk control inputs to requirements).
  • REG-IEC62304-SWRM (Clause 7 controls in requirements).
  • ISO/IEC 25010 (informative quality characteristics for requirement completeness).

Changelog

  • 1.0.0 (2026-05-21): Initial skill for IEC 62304 5.2 software requirements analysis.
This skill doesn’t include stateful context yet, instructions only. Learn about stateful skills.

Security

Loading security scan...

Reviews (0)

Browse all →
meddev-authenticationDefine secure user/device authentication, session management, and RBAC suitable for medical device risk profiles. Use when working on authentication in medical device software.0 installsmeddev-state-machinesDefine explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. Use when working on state machines in medical device software.0 installsmeddev-change-controlDefine controlled change-request workflow for software: impact analysis, approvals, verification scope, and regulatory submission flags. Configuration identification and baselines are in DOC-SCM (IEC 62304 Clause 8.1, 8.3); approved implementation and re-verification align with 8.2. Use when working on change control in medical device software.0 installsCONN-USBImplement safe USB device connectivity: class selection, enumeration handling, data validation, electrical and safety considerations.0 installsmeddev-ai-ml-medical-device-softwareAddress machine learning inside the regulated product (not LLM coding assistants): Good Machine Learning Practice (GMLP), training/validation data integrity, Predetermined Change Control Plans (PCCP) where applicable, drift monitoring, and linking models to ISO 14971 and software lifecycle controls. Use when working on ai ml medical device software in medical device software.0 installsTEST-HILValidate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.0 installs

More from Medical Device Skills

View source →

More Docs skills

Browse category →

Frequently asked questions about DOC-SW-REQ

What does the DOC-SW-REQ skill do?

Guide creation, verification, and maintenance of software system requirements derived from system needs (IEC 62304:2006+A1:2015, 5.2)—with content appropriate to the device, risk controls embedded for Class B/C, and evidence that requirements are testable and traceable. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.

How do I install the DOC-SW-REQ skill?

Run `npx @skills-hub-ai/cli install meddev-skills-doc-sw-req` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-doc-sw-req/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.

Which AI tools does DOC-SW-REQ work with?

DOC-SW-REQ runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.

Is the DOC-SW-REQ skill free?

Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.

How do I use DOC-SW-REQ after installing it?

In Claude Code, type `/meddev-skills-doc-sw-req` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.

Can I share the DOC-SW-REQ skill with my team?

Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.