Skip to main content
BuildAI reviewed Jul 21, 2026

CONN-WIFI

Secure and robust WiFi connectivity for medical devices: WPA3/enterprise auth, certificate management, coexistence, resilience, and hospital network integration.

v1.0.0New

Unsigned, install at your own risk

Unverified

This skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.

Install this skill

No account required. Pick your tool, or use the command that detects it for you.

Run in your terminal. It detects your AI tool.

npx @skills-hub-ai/cli install meddev-skills-conn-wifi
Or get the file:
Browse all CLI commands →
Manual setup by platform

Claude Code

~/.claude/skills/meddev-skills-conn-wifi/SKILL.md

Setup guide →
0Save

Instructions

WiFi for Medical Devices

Purpose

Secure and robust WiFi connectivity for medical devices: WPA3/enterprise auth, certificate management, coexistence, resilience, and hospital network integration.

When to Apply

  • Adding or modifying WiFi connectivity, security settings, or cert handling.
  • Hospital/enterprise deployments; PHI transport over WiFi.

Requirements (testable)

  1. Security Mode: Prefer WPA3 (SAE/Enterprise); if WPA2-Enterprise, enforce strong EAP (e.g., TLS/TTLS) and server cert validation. Rationale: confidentiality/integrity.
  2. Certificate Management: Validate server certificates (chain/expiry/CRL/OCSP where feasible); store client cert/keys securely; support rotation. Rationale: trust assurance.
  3. Network Resilience: Implement reconnect with backoff; detect captive portals and fail closed for clinical data paths. Rationale: availability without unsafe fallback.
  4. Coexistence: Configure to minimize interference with BLE/critical comms; test latency/jitter impact. Rationale: performance and safety timing.
  5. Power Considerations: Manage DTIM/listen intervals; avoid unnecessary scans; document impact on battery. Rationale: power budget.
  6. PHI Handling: Always transport PHI over TLS 1.3 (or strong 1.2) on top of WiFi; do not rely solely on link-layer security. Rationale: defense in depth.
  7. Logging: Log association/auth failures and disconnect reasons without leaking sensitive credentials; rate-limit logs. Rationale: diagnostics without leakage.

Recommended Practices

  • Use per-device credentials; avoid shared PSKs in clinical deployments.
  • Prefer wired/Ethernet fallback for critical fixed devices when possible.
  • Cache known-good networks; avoid auto-connecting to open SSIDs.
  • Align WiFi channel/power config with hospital policies.

Patterns

Server cert validation (pseudocode):

// REQ-WIFI-CERT-01; TEST-WIFI-05
bool validate_server_cert(cert_t *c) {
    return chain_ok(c) && !expired(c) && ocsp_good(c);
}

Reconnect with backoff:

// REQ-WIFI-RESIL-02; TEST-WIFI-07
for (int i = 0; i < MAX_RETRIES; i++) {
    if (wifi_connect()) break;
    sleep_ms(100 * (1 << i)); // capped elsewhere
}

PHI only over TLS:

// REQ-WIFI-PHI-03; TEST-WIFI-09
int send_phi(const uint8_t *buf, size_t len) {
    if (!tls_session_ready()) return -1;
    return tls_send(buf, len);
}

Anti-Patterns (risks)

  • Using WPA2-PSK with shared keys in hospitals -> risk: credential sprawl, MITM.
  • Skipping server cert validation -> risk: rogue AP/evil twin.
  • Sending PHI over plaintext HTTP on “secured” WiFi -> risk: data exposure.
  • Infinite aggressive reconnect loop -> risk: power drain, DoS on AP.
  • Ignoring coexistence -> risk: BLE control path jitter/drops.

Verification Checklist

  • WPA3 or strong WPA2-Enterprise configured; server cert validation enforced.
  • Client creds/certs stored securely; rotation supported/tested.
  • Reconnect/backoff implemented; captive portal detection fails closed for clinical data.
  • Coexistence tested (WiFi + BLE/critical comms); parameters tuned.
  • PHI only over TLS; link-layer security not sole control.
  • Logs capture association/auth failures without sensitive data; rate-limited.
  • Power impact assessed (DTIM, scans) and within budget.

Traceability

  • Requirements REQ-WIFI-### linked to tests TEST-WIFI-###; map to cybersecurity risks.

References

  • Wi-Fi Alliance WPA3 specifications.
  • NIST SP 800-153 (WLAN security); informative.
  • FDA Cybersecurity Premarket Guidance; IEC 60601-1-2 (EMC/coexistence).

Changelog

  • 1.0.0 (2026-01-04): Initial WiFi medical connectivity skill with security, cert, and coexistence guidance.

Audit History

  • 2026-01-04: Audit performed. Verified:
    • WPA3 references to Wi-Fi Alliance specifications accurate
    • NIST SP 800-153 (WLAN security) correctly referenced as informative
    • IEC 60601-1-2 reference appropriate for EMC/coexistence
This skill doesn’t include stateful context yet, instructions only. Learn about stateful skills.

Security

Loading security scan...

Reviews (0)

Browse all →
meddev-authenticationDefine secure user/device authentication, session management, and RBAC suitable for medical device risk profiles. Use when working on authentication in medical device software.0 installsmeddev-state-machinesDefine explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. Use when working on state machines in medical device software.0 installsmeddev-change-controlDefine controlled change-request workflow for software: impact analysis, approvals, verification scope, and regulatory submission flags. Configuration identification and baselines are in DOC-SCM (IEC 62304 Clause 8.1, 8.3); approved implementation and re-verification align with 8.2. Use when working on change control in medical device software.0 installsCONN-USBImplement safe USB device connectivity: class selection, enumeration handling, data validation, electrical and safety considerations.0 installsmeddev-ai-ml-medical-device-softwareAddress machine learning inside the regulated product (not LLM coding assistants): Good Machine Learning Practice (GMLP), training/validation data integrity, Predetermined Change Control Plans (PCCP) where applicable, drift monitoring, and linking models to ISO 14971 and software lifecycle controls. Use when working on ai ml medical device software in medical device software.0 installsTEST-HILValidate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.0 installs

More from Medical Device Skills

View source →

More Build skills

Browse category →
senior-frontendBuild and review React, Next.js, TypeScript or Tailwind frontends: components, scaffolding, performance and bundle size. Use whenever the user wants a new component or app, a page feels slow, the bundle is too big, or asks for a frontend code review.643 installsui-design-systemUse when building a design system: tokens, component docs, responsive scales or developer handoff. Generates tokens with design_token_generator.py.546 installsfrontend-designGuidance for distinctive, intentional visual design when building new UI or reshaping an existing one. Helps with aesthetic direction, typography, and making choices that don't read as templated defaults.354 installssenior-backendBuild and fix backend services: REST or GraphQL APIs, auth, microservices, PostgreSQL queries, migrations and load tests. Use whenever the user's API is slow or broken, needs login or auth added, a schema change, or a new endpoint or service scaffolded.253 installsself-improving-agentCurate what the agent has learned into durable project knowledge. Reviews Claude Code auto-memory (MEMORY.md and its topic files) for learnings worth keeping, promotes proven ones into CLAUDE.md or .claude/rules/, records a correction as a lesson that persists across sessions, prunes stale or duplicate entries, and turns a recurring fix into a reusable skill. Use whenever the user asks what you have learned or saved about the project, which memories should become permanent rules, to remember a lesson or stop repeating a mistake, or to clean up, audit or check memory health.180 installsusing-superpowersUse when starting any conversation - establishes how to find and use skills, requiring skill invocation before ANY response including clarifying questions146 installs

Frequently asked questions about CONN-WIFI

What does the CONN-WIFI skill do?

Secure and robust WiFi connectivity for medical devices: WPA3/enterprise auth, certificate management, coexistence, resilience, and hospital network integration. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.

How do I install the CONN-WIFI skill?

Run `npx @skills-hub-ai/cli install meddev-skills-conn-wifi` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-conn-wifi/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.

Which AI tools does CONN-WIFI work with?

CONN-WIFI runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.

Is the CONN-WIFI skill free?

Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.

How do I use CONN-WIFI after installing it?

In Claude Code, type `/meddev-skills-conn-wifi` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.

Can I share the CONN-WIFI skill with my team?

Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.