CONN-INTEROP
Enable safe and standards-aligned interoperability: HL7 FHIR/IHE profiles, data formats, terminology mapping, and API design for medical data exchange.
Unsigned, install at your own risk
UnverifiedThis skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.
Install this skill
No account required. Pick your tool, or use the command that detects it for you.
Run in your terminal. It detects your AI tool.
npx @skills-hub-ai/cli install meddev-skills-conn-interopManual setup by platform
Claude Code
~/.claude/skills/meddev-skills-conn-interop/SKILL.md
Instructions
Medical Device Interoperability
Purpose
Enable safe and standards-aligned interoperability: HL7 FHIR/IHE profiles, data formats, terminology mapping, and API design for medical data exchange.
When to Apply
- Designing or updating device APIs, data exchange, or integrations with HIS/EMR/cloud.
- Handling PHI or clinical decisions based on exchanged data.
Requirements (testable)
- Standards Use: Prefer established standards (HL7 FHIR, HL7 v2 where applicable, IHE profiles) for relevant data flows; document conformance. Rationale: interoperability and clarity.
- Terminology: Use standard vocabularies (SNOMED CT, LOINC) for clinical concepts; map device codes to standard codes. Rationale: semantic consistency.
- Data Integrity: Validate messages (schema/length/range); apply checksums/hashes over payloads where appropriate; reject/flag invalid data. Rationale: correctness.
- Security & Privacy: Protect PHI with TLS 1.3+; enforce authz (scopes/roles); log access; minimize data shared. Rationale: confidentiality/integrity.
- Error Handling: Provide clear, standard error responses; fail safe; no silent truncation. Rationale: predictable integration.
- Traceability: Log message IDs, timestamps, and correlation IDs; link to requirements/tests; keep audit for safety-relevant exchanges. Rationale: accountability.
- Interop Risks: Document interop-related hazards (misinterpretation, time sync, version mismatch) and mitigations. Rationale: safety.
Recommended Practices
- Provide versioned APIs and explicit capability statements (e.g., FHIR CapabilityStatement).
- Time-sync devices (NTP/PTP) to avoid timestamp drift in clinical workflows.
- Use contract tests against partner systems; include negative cases.
- Avoid custom extensions unless necessary; document them clearly.
Patterns
FHIR-like JSON validation (pseudo):
# REQ-INTOP-VALID-01; TEST-INTOP-04
def validate_observation(obs: dict) -> bool:
required = ["resourceType", "status", "code", "subject", "effectiveDateTime"]
if obs.get("resourceType") != "Observation":
return False
return all(k in obs for k in required)
Terminology mapping table (YAML):
# REQ-INTOP-TERM-02
device_code: FLOW_RATE
loinc: 8310-5
display: Infusion flow rate
Error response:
// REQ-INTOP-ERR-03; TEST-INTOP-07
{ "error": "invalid-parameter", "detail": "missing code" }
Anti-Patterns (risks)
- Custom proprietary formats without mapping -> risk: misinterpretation by HIS/EMR.
- Sending PHI over plaintext or weak TLS -> risk: data breach.
- Silent acceptance of invalid messages -> risk: wrong clinical decisions.
- No time sync -> risk: misleading timestamps in therapy/diagnostics.
Verification Checklist
- Standards selected and documented; conformance statements present.
- Terminology mapped to SNOMED/LOINC (or applicable); mappings versioned.
- Message validation implemented; invalid data rejected/logged.
- TLS 1.3+ and authz enforced; PHI minimized; access logged.
- Error responses clear and standard; no silent truncation.
- Interop hazards documented with mitigations/tests.
- Time synchronization implemented and monitored.
Traceability
- Requirements
REQ-INTOP-###linked to contract/interop testsTEST-INTOP-###; logs maintain correlation IDs for message tracing.
References
- HL7 FHIR R4/R5; HL7 v2 where applicable.
- IHE profiles relevant to devices (e.g., PCD-01, DEC).
- FDA interoperability guidance (2017).
- IEC 62304/ISO 14971 for risk integration.
Changelog
- 1.0.0 (2026-01-04): Initial interoperability skill with standards use, validation, terminology, and security guidance.
Audit History
- 2026-01-04: Audit performed. Verified:
- HL7 FHIR R4/R5 references accurate
- IHE profiles (PCD-01, DEC) correctly mentioned
- FDA interoperability guidance (2017) reference verified
- SNOMED CT and LOINC terminology references appropriate
Security
Reviews (0)
Related skills
Browse all →More from Medical Device Skills
View source →More Build skills
Browse category →Frequently asked questions about CONN-INTEROP
What does the CONN-INTEROP skill do?
Enable safe and standards-aligned interoperability: HL7 FHIR/IHE profiles, data formats, terminology mapping, and API design for medical data exchange. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.
How do I install the CONN-INTEROP skill?
Run `npx @skills-hub-ai/cli install meddev-skills-conn-interop` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-conn-interop/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.
Which AI tools does CONN-INTEROP work with?
CONN-INTEROP runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.
Is the CONN-INTEROP skill free?
Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.
How do I use CONN-INTEROP after installing it?
In Claude Code, type `/meddev-skills-conn-interop` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.
Can I share the CONN-INTEROP skill with my team?
Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.