Skip to main content
BuildAI reviewed Jul 21, 2026

CONN-INTEROP

Enable safe and standards-aligned interoperability: HL7 FHIR/IHE profiles, data formats, terminology mapping, and API design for medical data exchange.

v1.0.0New

Unsigned, install at your own risk

Unverified

This skill has no cryptographic signature attached. We can't verify the contents match what the publisher intended.

Install this skill

No account required. Pick your tool, or use the command that detects it for you.

Run in your terminal. It detects your AI tool.

npx @skills-hub-ai/cli install meddev-skills-conn-interop
Or get the file:
Browse all CLI commands →
Manual setup by platform

Claude Code

~/.claude/skills/meddev-skills-conn-interop/SKILL.md

Setup guide →
0Save

Instructions

Medical Device Interoperability

Purpose

Enable safe and standards-aligned interoperability: HL7 FHIR/IHE profiles, data formats, terminology mapping, and API design for medical data exchange.

When to Apply

  • Designing or updating device APIs, data exchange, or integrations with HIS/EMR/cloud.
  • Handling PHI or clinical decisions based on exchanged data.

Requirements (testable)

  1. Standards Use: Prefer established standards (HL7 FHIR, HL7 v2 where applicable, IHE profiles) for relevant data flows; document conformance. Rationale: interoperability and clarity.
  2. Terminology: Use standard vocabularies (SNOMED CT, LOINC) for clinical concepts; map device codes to standard codes. Rationale: semantic consistency.
  3. Data Integrity: Validate messages (schema/length/range); apply checksums/hashes over payloads where appropriate; reject/flag invalid data. Rationale: correctness.
  4. Security & Privacy: Protect PHI with TLS 1.3+; enforce authz (scopes/roles); log access; minimize data shared. Rationale: confidentiality/integrity.
  5. Error Handling: Provide clear, standard error responses; fail safe; no silent truncation. Rationale: predictable integration.
  6. Traceability: Log message IDs, timestamps, and correlation IDs; link to requirements/tests; keep audit for safety-relevant exchanges. Rationale: accountability.
  7. Interop Risks: Document interop-related hazards (misinterpretation, time sync, version mismatch) and mitigations. Rationale: safety.

Recommended Practices

  • Provide versioned APIs and explicit capability statements (e.g., FHIR CapabilityStatement).
  • Time-sync devices (NTP/PTP) to avoid timestamp drift in clinical workflows.
  • Use contract tests against partner systems; include negative cases.
  • Avoid custom extensions unless necessary; document them clearly.

Patterns

FHIR-like JSON validation (pseudo):

# REQ-INTOP-VALID-01; TEST-INTOP-04
def validate_observation(obs: dict) -> bool:
    required = ["resourceType", "status", "code", "subject", "effectiveDateTime"]
    if obs.get("resourceType") != "Observation":
        return False
    return all(k in obs for k in required)

Terminology mapping table (YAML):

# REQ-INTOP-TERM-02
device_code: FLOW_RATE
loinc: 8310-5
display: Infusion flow rate

Error response:

// REQ-INTOP-ERR-03; TEST-INTOP-07
{ "error": "invalid-parameter", "detail": "missing code" }

Anti-Patterns (risks)

  • Custom proprietary formats without mapping -> risk: misinterpretation by HIS/EMR.
  • Sending PHI over plaintext or weak TLS -> risk: data breach.
  • Silent acceptance of invalid messages -> risk: wrong clinical decisions.
  • No time sync -> risk: misleading timestamps in therapy/diagnostics.

Verification Checklist

  • Standards selected and documented; conformance statements present.
  • Terminology mapped to SNOMED/LOINC (or applicable); mappings versioned.
  • Message validation implemented; invalid data rejected/logged.
  • TLS 1.3+ and authz enforced; PHI minimized; access logged.
  • Error responses clear and standard; no silent truncation.
  • Interop hazards documented with mitigations/tests.
  • Time synchronization implemented and monitored.

Traceability

  • Requirements REQ-INTOP-### linked to contract/interop tests TEST-INTOP-###; logs maintain correlation IDs for message tracing.

References

  • HL7 FHIR R4/R5; HL7 v2 where applicable.
  • IHE profiles relevant to devices (e.g., PCD-01, DEC).
  • FDA interoperability guidance (2017).
  • IEC 62304/ISO 14971 for risk integration.

Changelog

  • 1.0.0 (2026-01-04): Initial interoperability skill with standards use, validation, terminology, and security guidance.

Audit History

  • 2026-01-04: Audit performed. Verified:
    • HL7 FHIR R4/R5 references accurate
    • IHE profiles (PCD-01, DEC) correctly mentioned
    • FDA interoperability guidance (2017) reference verified
    • SNOMED CT and LOINC terminology references appropriate
This skill doesn’t include stateful context yet, instructions only. Learn about stateful skills.

Security

Loading security scan...

Reviews (0)

Browse all →
meddev-authenticationDefine secure user/device authentication, session management, and RBAC suitable for medical device risk profiles. Use when working on authentication in medical device software.0 installsmeddev-state-machinesDefine explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. Use when working on state machines in medical device software.0 installsmeddev-change-controlDefine controlled change-request workflow for software: impact analysis, approvals, verification scope, and regulatory submission flags. Configuration identification and baselines are in DOC-SCM (IEC 62304 Clause 8.1, 8.3); approved implementation and re-verification align with 8.2. Use when working on change control in medical device software.0 installsCONN-USBImplement safe USB device connectivity: class selection, enumeration handling, data validation, electrical and safety considerations.0 installsmeddev-ai-ml-medical-device-softwareAddress machine learning inside the regulated product (not LLM coding assistants): Good Machine Learning Practice (GMLP), training/validation data integrity, Predetermined Change Control Plans (PCCP) where applicable, drift monitoring, and linking models to ISO 14971 and software lifecycle controls. Use when working on ai ml medical device software in medical device software.0 installsTEST-HILValidate software with real or representative hardware, sensors, actuators, and timing, to uncover integration and safety issues not visible in simulation.0 installs

More from Medical Device Skills

View source →

More Build skills

Browse category →
senior-frontendBuild and review React, Next.js, TypeScript or Tailwind frontends: components, scaffolding, performance and bundle size. Use whenever the user wants a new component or app, a page feels slow, the bundle is too big, or asks for a frontend code review.642 installsui-design-systemUse when building a design system: tokens, component docs, responsive scales or developer handoff. Generates tokens with design_token_generator.py.546 installsfrontend-designGuidance for distinctive, intentional visual design when building new UI or reshaping an existing one. Helps with aesthetic direction, typography, and making choices that don't read as templated defaults.353 installssenior-backendBuild and fix backend services: REST or GraphQL APIs, auth, microservices, PostgreSQL queries, migrations and load tests. Use whenever the user's API is slow or broken, needs login or auth added, a schema change, or a new endpoint or service scaffolded.252 installsself-improving-agentCurate what the agent has learned into durable project knowledge. Reviews Claude Code auto-memory (MEMORY.md and its topic files) for learnings worth keeping, promotes proven ones into CLAUDE.md or .claude/rules/, records a correction as a lesson that persists across sessions, prunes stale or duplicate entries, and turns a recurring fix into a reusable skill. Use whenever the user asks what you have learned or saved about the project, which memories should become permanent rules, to remember a lesson or stop repeating a mistake, or to clean up, audit or check memory health.179 installsusing-superpowersUse when starting any conversation - establishes how to find and use skills, requiring skill invocation before ANY response including clarifying questions146 installs

Frequently asked questions about CONN-INTEROP

What does the CONN-INTEROP skill do?

Enable safe and standards-aligned interoperability: HL7 FHIR/IHE profiles, data formats, terminology mapping, and API design for medical data exchange. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.

How do I install the CONN-INTEROP skill?

Run `npx @skills-hub-ai/cli install meddev-skills-conn-interop` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-conn-interop/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.

Which AI tools does CONN-INTEROP work with?

CONN-INTEROP runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.

Is the CONN-INTEROP skill free?

Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.

How do I use CONN-INTEROP after installing it?

In Claude Code, type `/meddev-skills-conn-interop` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.

Can I share the CONN-INTEROP skill with my team?

Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.