Medical Device State Machine Design
Purpose
Define explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes.
When to Apply
- Control logic, therapy delivery flows, connectivity/session management, alarm handling.
- Any feature with discrete modes and safety-relevant transitions.
Requirements (testable)
- Explicit States: Enumerate states, including safe/error states; no implicit fall-through. Rationale: determinism.
- Guarded Transitions: Define entry/exit criteria and guards for each transition; reject invalid transitions. Rationale: prevent unsafe paths.
- Safe State: Define and implement a safe state reachable from any error condition; ensure outputs are rendered safe. Rationale: bounded failure.
- Timeout Handling: Include timeouts for blocking/wait states; transition to safe/error with annunciation. Rationale: avoid hangs.
- Reset/Recovery: Define recovery paths and conditions to re-enter operational states safely. Rationale: controlled restart.
- Traceability: Tag states/transitions with requirement and risk IDs; test each transition. Rationale: verification coverage.
Recommended Practices
- Use table-driven or hierarchical state machines to reduce branching complexity.
- Keep side effects on exit/entry functions; avoid scattered effects.
- Include instrumentation for state transition logging (with debounce to avoid log storms).
- Use static analysis to catch incomplete switch/enum handling.
Patterns
Table-driven state machine (C):
// REQ-SM-10, HZ-07, RISK-CTRL-19
typedef enum { ST_IDLE, ST_PRIME, ST_RUN, ST_ALARM, ST_SAFE } state_t;
typedef state_t (*handler_fn)(void);
typedef struct { state_t state; handler_fn fn; } state_entry_t;
static state_t handle_idle(void) { /* ... */ return ST_PRIME; }
static state_t handle_prime(void) { /* ... */ return ST_RUN; }
static state_t handle_run(void) { if (fault()) return ST_SAFE; return ST_RUN; }
static state_t handle_alarm(void) { /* annunciate */ return ST_SAFE; }
static state_t handle_safe(void) { stop_outputs(); return ST_SAFE; }
static const state_entry_t table[] = {
{ST_IDLE, handle_idle},
{ST_PRIME, handle_prime},
{ST_RUN, handle_run},
{ST_ALARM, handle_alarm},
{ST_SAFE, handle_safe},
};
Invalid transition guard:
// REQ-SM-21; TEST-SM-05
bool can_transition(state_t from, state_t to) {
switch (from) {
case ST_RUN: return (to == ST_ALARM || to == ST_SAFE);
case ST_IDLE: return (to == ST_PRIME);
default: return to == ST_SAFE; // fallback to safe only
}
}
Timeout to safe state:
// REQ-SM-30; TEST-SM-08
if (timer_expired(&t_wait)) {
set_state(ST_SAFE);
alarm_timeout();
}
Anti-Patterns (risks)
- Implicit default transitions in switch without handling all states -> risk: undefined behavior.
- No safe state or unreachable safe transitions -> risk: uncontrolled outputs.
- Mixing side effects in multiple places instead of entry/exit -> risk: inconsistent behavior.
- Lack of timeout handling -> risk: hang in unsafe intermediate mode.
Verification Checklist
- States enumerated (including safe/error) and documented.
- Guards defined for all transitions; invalid transitions rejected.
- Safe state reachable from any error; outputs rendered safe.
- Timeouts implemented for wait states; alarm/annunciation verified.
- Recovery/reset paths defined and tested.
- Tests cover each state and transition; traceability tags present.
- Static analysis/lint checks ensure exhaustive switch over states.
Traceability
- Map
REQ-SM-###to states/transitions andTEST-SM-###to transition coverage. - Log state transitions with IDs to support post-incident analysis.
References
- IEC 62304 expectations for state control (design/implementation discipline).
- ISO 14971 linkage for hazard controls via safe states.
Changelog
- 1.0.0 (2026-01-04): Initial state machine skill with guarded transitions, safe state patterns, and coverage checklist.
Audit History
- 2026-01-04: Audit performed. Verified:
- State machine patterns are technically sound
- Safe state concepts align with IEC 62304 and ISO 14971 hazard control principles
- Code examples compile correctly (C11 compliant)
Security
Reviews (0)
Related skills
Browse all →More from Medical Device Skills
View source →More Build skills
Browse category →Frequently asked questions about ARCH-STATE-MACHINES
What does the ARCH-STATE-MACHINES skill do?
Define explicit, testable state machines with safe states, controlled transitions, and error handling suited to medical device safety classes. It's a reusable SKILL.md instruction set that loads into your AI coding assistant on demand, no prompt engineering, no copy-pasting every session.
How do I install the ARCH-STATE-MACHINES skill?
Run `npx @skills-hub-ai/cli install meddev-skills-arch-state-machines` from your terminal. The CLI writes the SKILL.md to the correct location for your AI tool (e.g. ~/.claude/skills/meddev-skills-arch-state-machines/ for Claude Code or ~/.cursor/skills/ for Cursor with --target cursor) and adds it to your project's .skills.json lockfile.
Which AI tools does ARCH-STATE-MACHINES work with?
ARCH-STATE-MACHINES runs in Claude Code. It follows the open Agent Skills standard (SKILL.md), so the same skill works in every supported tool without modification.
Is the ARCH-STATE-MACHINES skill free?
Yes. Every skill on skills-hub.ai is free and open-source. There are no premium tiers, paywalls, or usage limits. You only pay for whatever AI assistant you're already using.
How do I use ARCH-STATE-MACHINES after installing it?
In Claude Code, type `/meddev-skills-arch-state-machines` (or whatever slash command the skill registers) and the AI follows the skill's instructions immediately. You can also reference it by name in natural language, your AI loads the skill into context when relevant.
Can I share the ARCH-STATE-MACHINES skill with my team?
Yes. Commit your project's .skills.json lockfile and teammates run `npx @skills-hub-ai/cli install` (no args) to install every skill at the exact version you pinned. Organization-scoped installs work via skills-hub.ai organizations.